Carriere®️ M-Series™️ Wires

Carriere®️ M-Series™️ Wires

Introducing
Carriere®️ M-Series™️ Wires

Introducing the All-New M-Series™ Wires, including .015 Cu™ Nitanium® Wire and the innovative 3-Wire Sequence.

M-Series Wires are designed to:
• Enable a simplified wire progression protocol
• Reduce the number of wires used
• Finish cases in about 12 months

mseries wires

Integral to the SAGITTAL FIRST Treatment Philosophy is the use of the Carriere® MOTION 3D™ Appliance to correct AP discrepancies and stimulate initial tooth movement. This fosters easier transitions into larger wires earlier in treatment, less time in braces, and shorter overall treatment times.

sagittal first m series

Specifications

Wire Sequencing Protocol

M-Series Wire Sequence – for Metal Bracket Systems

WIRE NAME DESCRIPTION OBJECTIVE TIME IN TREATMENT NUMBER OF APPOINTMENTS
(5-6 WEEK INTERVALS)
M-ONE .015 Cu Nitanium 27° with EZ Stops™ Begin leveling, aligning, and rotations 5-6 weeks 1 appointment
M-TWO .020 x .020 Cu Nitanium 35° with EZ Stops Complete leveling, aligning, and elimination of rotations. Arch development is initiated, 3 dimensional control of wire will begin to initial torque control 6-18 weeks, based on complexity and clinical judgement 2-3 appointments
M-THREE BETA .019 x .025 Beta Titanium Detailing and finishing 8-12 weeks 2-3 appointments

All M-Series Wires are available in the D-LX™ archform and are packaged in single pouches in packs of 10.

Optional Wires

WIRE NAME DESCRIPTION OBJECTIVE TIME IN TREATMENT NUMBER OF APPOINTMENTS
(5-6 WEEK INTERVALS)
M-ONE.FIVE .018 Cu Nitanmium 27° with EZ Stops Used in small number of cases for stubborn rotations prior to placing M-TWO wire 4-6 weeks 1-2 appointments

Wire Sequencing Protocol

M-Series Wire Sequence – for Ceramic Bracket Systems

WIRE NAME DESCRIPTION OBJECTIVE TIME IN TREATMENT NUMBER OF APPOINTMENTS
(5-6 WEEK INTERVALS)
M-ONE .015 Cu Nitanium Begin to eliminate rotations and align 5-6 weeks 1 appointment
M-TWO .020 x .020 Cu Nitanium Complete leveling, aligning, and elimination of rotations. Arch development is initiated, 3 dimensional control of wire will begin initial torque control 6-18 weeks, based on complexity and clinical judgement 2-3 appointments
M-TWO.FIVE .019 x .025 Cu Nitanium For final bracket alignment prior to CNA 3-4 weeks 1 appointment
M-THREE BETA .019 x .025 Beta (CNA) Detailing and finishing 8-12 weeks 2-3 appointments

Optional Wires

WIRE NAME DESCRIPTION OBJECTIVE TIME IN TREATMENT NUMBER OF APPOINTMENTS
(5-6 WEEK INTERVALS)
M-ONE.FIVE .018 Cu Nitanmium Used in small number of cases for stubborn rotations prior to placing .020 x .020 4-6 weeks 1-2 appointments
M-THREE STEEL .019 x .025 Stainless Steel Surgical stabilization wire placed prior to surgery and/or to complete expansion in stubborn cases 8-12 weeks 2-3 appointments

Brochures

Click here to download the Carriere M-Series Wires Brochure.